Lab 4 Tips

Lab 4 is an introduction to the equipment found
in the CS150 lab. The most important tool that you will be useful
to understand and use is the oscilliscope. It will be your debugging
tool for future labs and projects. A good understanding of this
tool and how to use to analyze digital signals and measure delays
will be very useful. So take good care to understanding this tool.
KEY: Become familiar with the digital probes of
the oscilliscope. Learn to read digital signals, learn to trigger
on certain patterns, and learn to freeze and measure delays and
bits from the digital waveforms.
Click here
for a TXT version of the notes.
[BACK]
- You do not need the XILINX Project Manager software
to load a bit file to the XILINX board.
- Open the Debugger loader by going to the Start
Menu --> Xilinx Foundation... --> Accessories --> Hardware
Debugger.
- This is rather counter-intuitive; when you load
a BIT-file onto the XILINX board, do NOT open a project. Rather,
create a NEW PROJECT and load the bit file from there.
- Again, you will need to map the CS150 folder
to a drive under \\fileservice\cs150 and copy the LAB4 folder
to your local directory or desktop.
- Reading the bits on the oscilliscope can be
a little tricky.
- On the screen of the oscilliscope, TIME
increases from left to right. Therefore the first bit you receive
will be on the left side of the screen and the last bit you receive
will be on the right side.
- The bits that output from the ROM are sent out
from least significant bit first (bit 0 first) to the most significant
bit last (bit 15 last). This means that reading the bits from left
to right, you will have to reverse the bits so that they are in
correct bit-wise order.
- Also since it will be easier to show us TAs
the number in hexidecimal form, it would be easiest to "read"
the bits in groups of four. Use the CURSOR function and set
one cursor at the beginning of the four-bit group and the second
cursor at the end. Lock the two cursors together and use them to
mark off each four bits.
Several things that will make your life easier
for the lab, follow the below instruction:
- In the part of the lab where you are required
to use the analog probes in measuring the signal coming out of the
ROM, replace the analog probes with the digital pin-out probes.
They are the small spaghetti-like probes that are already attached
to the oscilliscope.
- Another revision is the last part of the lab.
Rather than triggering on the counter at 1110, and then step
the clock to 1111 use a different method.
- Using the PATTERN option on the oscilliscope,
set the combination of bits, depending on which probe you used,
to the 2nd through 4th bit being set to H, H, H and the 1st
bit being set at L-->H (which on the oscilliscope is represented
by a small arrow going low to high).
- Also rather than running the scope on RUN
mode, set it to SINGLE mode, which will trigger on the first
pattern and freeze the waveform.
- Let the oscilliscope trigger on that combo and
you will be able to observe the final output without having to step
the clock. You just have to start it and the correct waveform will
be captured.
[BACK]
|